화재 지연 제 케이블 화재 방지 전원 케이블 FRC
항구: | Shanghai |
결제 조건: | L/C,D/P,T/T,Western Union |
공급 능력: | 10000 미터 당 Day |
원래 장소: | Shanghai 중국 |
유명 상표: | xinxin |
모델 번호: | 중간 전압 |
절연재: | XLPE |
유형: | 중간 전압 |
신청: | 발전소 |
지휘자 물자: | 구리 |
재킷: | PVC |
갑옷: | 역/ swa |
허용 작동 온도: | 90℃ |
표준: | IEC 60502, IEC 60228, IEC 60332, CE, kema |
배송 상세 정보: | 10 일 접수 입금 후 |
포장 상세 정보: | 목재 드럼 또는 customerized |
Applications
Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.
Standards
International: IEC 60502-2, IEC 60228
China: GB/T 12706.2-2008
Other standards such as BS,DIN and ICEA upon request
Technical data
Rated voltage: 0.6/1kV, 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV
Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.
Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables
15 x cable O.D for single-core armoured cables
15 x cable O.D for multi-core non-armoured cables
12 x cable O.D for multi-core armoured cables
Certificates
CE, RoHS, CCC, KEMA and more others at request
Specifications
YJV |
Copper Conductor, XLPE Insulated, PVC Sheathed Power Cable |
For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed. |
YJLV |
Al. Conductor, XLPE Insulated, PVC Sheathed Power Cable |
|
YJY |
Copper Conductor, XLPE Insulated, PE Sheathed Power Cable |
For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed. |
YJLY |
Al. Conductor, XLPE Insulated, PE Sheathed Power Cable |
|
YJV22 |
XLPE Insulated,Steel Tape Armored,PVC Sheathed Power Cable |
Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces. |
YJLV22 |
Al. Insulated,Steel Tape Armored,PVC Sheathed Power Cable |
|
YJV32 |
Copper Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable |
Apply to shafts,water and soil,able to bear the larger positive pressure. |
YJLV32 |
Al.Conductor, XLPE Insulated, Fine Steel Wire Armored,PVC Sheathed Power Cable |
|
YJV42 |
Copper Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable |
For laying in shaft, water underground and large diference of level, able to bear external mechanical pressure and moderate pulling force. |
YJLV42 |
Al.Conductor, XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power Cable |
- Next: WDZAN CU/XLPE/PVC 3×2.5mm2 LSOH Sheathed Flame retardant Power Cable for safe use
- Previous: Medium voltage underground cable YE2SHSV,NAYCVVY,NA2XY,N2XY CABLE