11kv abc aerial bundle cable from china is applied to overhead power line with rated voltage 0.6/1kv and 10KV.
11kv abc aerial bundle cable from china is mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
1kv abc cable, 11kv abc cable, 33kv abc cable
1 .Type:Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop
a Duplex Service Drop
Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
b Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
c Quadruplex Service Drop
Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
2 . Construction
a Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.
b Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded
c Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request.
3. specification
Code Name |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000ft (lbs) |
Ampacity(amps) |
||||||
Size AWG |
Stranding |
Insulation Thickness(mls) |
Size AWG |
Stranding |
Breaking Strength(lbs) |
XLPE |
Poly |
XLPE |
Poly |
|
6201 ALLOY NEUTRAL-MESSENGER |
||||||||||
Minex |
6 |
Solid |
45 |
6 |
7 |
1,110 |
106.6 |
102.9 |
85 |
70 |
Hippa |
6 |
7 |
45 |
6 |
7 |
1,110 |
113.2 |
105.7 |
85 |
70 |
Prawn |
4 |
Solid |
45 |
4 |
7 |
1,760 |
158.4 |
154.1 |
115 |
90 |
Barnacles |
4 |
7 |
45 |
4 |
7 |
1,760 |
168.3 |
158.2 |
115 |
90 |
Shrimp |
2 |
7 |
45 |
2 |
7 |
2,800 |
253.7 |
239.7 |
150 |
120 |
Gammarus |
1/0 |
7 |
60 |
1/0 |
7 |
4,460 |
411.7 |
386.0 |
205 |
160 |
Leda |
1/0 |
19 |
60 |
1/0 |
7 |
4,460 |
402.7 |
386.0 |
205 |
160 |
Dungenese |
2/0 |
7 |
60 |
2/0 |
7 |
5,390 |
506.8 |
476.3 |
235 |
185 |
Cyclops |
2/0 |
19 |
60 |
2/0 |
7 |
5,390 |
495.3 |
476.3 |
235 |
185 |
Dlustra |
3/0 |
19 |
60 |
3/0 |
7 |
6,790 |
611.4 |
589.1 |
275 |
215 |
Lepas |
4/0 |
19 |
60 |
4/0 |
7 |
8,560 |
757.1 |
730.5 |
315 |
245 |
4. Standards
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474